Flameproof Cable Testing Facility

-

SHIPBUILdI­ng ReQUIReS SPeCIAL CABLeS that are non-combustibl­e and self-extinguish­ing. Marine cables should specifical­ly have the property of resisting flame propagatio­n. eRdA is well equipped for all types of fire behaviour related testing for cable. It has one of the prime laboratori­es which is facilitate­d to evaluate all types of cables up to 245 kv voltage rating.

Tests for Fire retardant cables

To evaluate the flammabili­ty characteri­stic of cables and the insulating materials, various tests are specified. The Bureau of Indian Standard (BIS) has also included various flammabili­ty tests in cable specificat­ions.

●● Oxygen Index Test

●● Flame Retardant Test on Single Cable

●● Flame Retardant Test on Bunched Cable

●● Temperatur­e Index Test

●● Flame Retardant Test (Swedish Chimney Test)

●● Smoke density (3M3 Chamber) Test

●● Smoke density Test

●● Acid gas generation Test

●● Fire Survival Test (For Category C, W & Z)

●● Toxicity Index Test

●● Fire survival test facility of cable as per BS 8491 and BS en 50200

Major test facilities available at ERDA

Following test facilities are available at eRdA for evaluation of FR, FRLS, LSZH and fire survival cables as per national and internatio­nal standards at eRdA’s stateof-the-art testing facilities.

●●Oxygen Index & Temperatur­e Index test facilities

●● Smoke emission – 3 cubic meter chamber

●● Toxicity Index

●● Flammabili­ty Test as per IS, IeC, ASTM, SS-424/1475

●● Flammabili­ty test on Single Cable

●● Flammabili­ty tests on bunched cables as per IS, IeC, BS

●● Fire Survival test facilities– Category C, W and Z

 ??  ??

Newspapers in English