Build It

Installing the rear sliding door

-

Creating a good connection with the garden is a key goal for any self builder – the question is, do you achieve that with sliders or bifolds? We faced that conundrum with the Build It House, and the original concept drawings showed bifolds, which concertina back to give you almost totally clear garden access when open. The downside, of course, is that there are more panels than with sliders – so the latter gives you a better glass-to-frame ratio. In the end, that’s what swung the decision for us.

We’ve gone for the Build It Award-winning THEEDGE2.0 thermally broken aluminium slider from Idsystems, on a supply-and-fit basis. It offers slim sightlines of just 20mm and good performanc­e for weather tightness, security and energy efficiency – all at an appealing price

point for such a high-spec product. A long-establishe­d UK glazed door supplier, Idsystems is still family owned and has a knack for innovation, so was a natural fit for this part of our project.

Ordering the slider

I’d assumed we’d need a fixed frame at one end of the run, with the doors sliding on a triple track (one of which would be redundant). But David Clarke, Idsystems’ marketing manager, suggested a plant-on panel could give a better aesthetic – largely because it would allow for a narrower twin track and a thinner external frame.

It was an easy decision to go with the plant-on: the fact is sliding doors are kept closed most of the year, so it’s all about maximising that view through the glass. When they are open, theedge2.0’s panels will stack flush, keeping sightlines nice and slim. While we could have colour-matched the unit with our windows, because those are in timber rather than aluminium, the hue would never be exactly the same. So we decided on RAL 7016 anthracite grey, which looks sleek and will blend into the garden setting. The double-glazed panels have low-e toughened glass on the inner pane, and 8.8mm clear laminated glass externally to deliver on safety and security.

Once we’d finalised the design, Idsystems’ contracts team got in touch with drawings and documentat­ion to sign. No stone is left unturned at this stage: after all, it’s not in anybody’s interests if the install team turns up on site to find that the doors don’t fit properly. Among other details, the six PDFS I received included in-depth notes on what to check to ensure the structural openings are correctly prepared.

By now, most of the work was already done – and I’d been in touch with Idsystems at key points to ensure they were happy. The ICF

closers to the sides of the openings provide fixing points. At the base the track can be screwed directly into the concrete, and into timber at the head. The few bits left to do at our end included cutting the insulating formwork back to the polystyren­e closers, chipping out the corners of the opening where the concrete pour was slightly over, and getting the screed in. With a five-week lead time between order and delivery of the doors, there was plenty of time to sort this – although the final bits of trimming happened on fitting day.

Final preparatio­ns

When Idsystems’ install team, Paul Shorter and Mark Williamson, arrived on site, the first thing we did was check out the structural opening to make sure it was as expected. Pretty quickly, we noticed a discrepanc­y – the screed had been poured to a depth of 55mm (rather than the intended 40mm). It looks like Screedflo did this to marry up with the insulation and underfloor heating build-up in the WC, which

makes sense. But this was the first Scott and I had heard about it! Thankfully, we had enough space at the head to raise the sliders up a little higher without compromisi­ng the look – and as we’ve not yet specified the patio make-up, we can easily accommodat­e this. It does mean we need to cement fill or dry-pack beneath the bottom track.

I’d imagined we would fit the track so it’s perfectly flush with the tiled finished floor level (FFL), which will sit 17mm above the screed. But Paul suggested going for a 3mm-4mm lip. This is just enough to reduce the amount of debris that might get kicked into the running channel, but not so high it becomes a trip hazard (apparently anything up to 7mm is fine). What’s more, apparently if you go completely flush, the tile grout lines are much more likely to crack.

The next big question was how deep the setback should be (ie how far back the door should sit in the external wall). A twin track is much thicker than a standard window frame – so it’s never going to match up completely – while the two outermost panels are at different points within the frame depth (in fact, the plant-on is slightly proud). It’s the same with any slider, of course, but accentuate­d where we have timber cladding on one side and render on the other. We agreed that the best visual effect would be achieved by lining up the plant-on so that the full thickness of the larch cladding is on show.

Installing the doors

With the details nailed down, Idsystems’ fitters cracked on with the install. Paul and Mark worked as a team, one putting together the frame segments, the other prepped the bottom of the opening with spacers and clearing any last remaining areas of high concrete. The damp proof membrane (DPM) is incorporat­ed into the system – taped and glued to the cill – rather than being laid into the base of the opening.

Once the full 4,208mm (H) x 2,488mm (H) aluminium frame was assembled, the guys lifted it in and got to work aligning it. Everything needs to be pretty much perfectly square, within a tolerance of maybe a millimetre or two, to ensure the running mechanisms operate smoothly. Then there was the issue of getting the setback perfectly right to show the doors and the cladding (not yet fitted alongside the door) in their best light – which had Paul nervously quadruple-checking dimensions before the screws went in. I’m delighted to say he got it spot on!

The glass panels on a slider like this weigh in at over 100kg each, so they’re added on site after the frame is squared, levelled and fixed. The team fits the empty panels first to check the operation and locking systems, before inserting the glass. Interestin­gly, the doors actually slide at their smoothest when they’re fully assembled and heavier.

The final piece of the puzzle was to clip in the beading and re-test the lock positions (which Paul did by attaching strips of masking tape to check the alignment of the multi-point). A few minor adjustment­s later, and our glazed slider was fully installed – all in less than a day.

Handover

Idsystems’ literature asks for the owner to be present for a handover – and I have to say it was a useful exercise. Paul went through the longterm maintenanc­e instructio­ns and gave clear guidance on how to care for the sliders over the coming days and weeks on site.

Your first thought is to cover the doors, for instance, but you need to give them 48 hours for the seals to fully dry before doing so. They shouldn’t be operated for at least 24 hours either (cue all keys being taken off site) and, once you do open them, it’s a good idea to protect the track to avoid constructi­on debris getting in there and potentiall­y damaging the mechanisms. There’s a bit of work for us to do to finish it off. For instance, we need to fill in a small bit of screed, which we were expecting – we deliberate­ly left it a little short so that it wouldn’t get in the way of the install. When we do that, we’ll need to ensure we wrap Idsystems’ DPM up the inside of the frame.

 ??  ?? 1 The Idsystems install team grind out the last few bits of high concrete 2 The DPM is taped and glued onto the door cill 3 Assembling the frame took less than an hour 4 The cladding detail at the plant-on side of the slider dictated the setback – but it was tricky to get right, as the panel gets added later on 5 The doors have been raised to give a very slight lip to the finished floor, to minimise the risk of dirt getting into the track 6 Ensuring everything’s level and square is crucial – otherwise it just won’t run smoothly. This stage is probably the most time-consuming 7 With the frame screwed in and the plant-on installed, there was an audible sigh of relief when Paul doublechec­ked the cladding would finish where we wanted it 8 The individual panels come without the glass, to make the lifting and install process easier 9 One of the glass panels is lifted into position. It’s then clipped into place with special beading 10 Applying masking tape to the locking side of the frame is an easy way to test the bolts are shooting through correctly, and adjust if necessary 11 Silicone sealant is run where needed, before the whole unit is wiped down using a special cleaning solution
12 The install team tends to leave the yellow sticker indicating the glass has been installed the right way round in place, so that building control can’t argue!
1 The Idsystems install team grind out the last few bits of high concrete 2 The DPM is taped and glued onto the door cill 3 Assembling the frame took less than an hour 4 The cladding detail at the plant-on side of the slider dictated the setback – but it was tricky to get right, as the panel gets added later on 5 The doors have been raised to give a very slight lip to the finished floor, to minimise the risk of dirt getting into the track 6 Ensuring everything’s level and square is crucial – otherwise it just won’t run smoothly. This stage is probably the most time-consuming 7 With the frame screwed in and the plant-on installed, there was an audible sigh of relief when Paul doublechec­ked the cladding would finish where we wanted it 8 The individual panels come without the glass, to make the lifting and install process easier 9 One of the glass panels is lifted into position. It’s then clipped into place with special beading 10 Applying masking tape to the locking side of the frame is an easy way to test the bolts are shooting through correctly, and adjust if necessary 11 Silicone sealant is run where needed, before the whole unit is wiped down using a special cleaning solution 12 The install team tends to leave the yellow sticker indicating the glass has been installed the right way round in place, so that building control can’t argue!
 ??  ??
 ??  ??