Copper alloy belt buckle plate (SF 2008)
* Examined surfaces under magnification
* Removed adhering corrosion using scalpel and cotton swabs of 50:50 industrial methylated spirit (IMS) and deionised water
* Thoroughly dried surfaces with cotton swabs of acetone
* Stabilised with benztriazole (BTA) a corrosive inhibitor
* Application by immersing under vacuum in 3% BTA in IMS
* Rinsed in IMS to remove excess BTA residue
*Applied two protective coats of lacquer: 15% Incralac in toluene