BBC Sky at Night Magazine

STEVE RICHARDS

EQUIPMENT EXPERT

- With Steve Richards

Following last month’s advice on bias frames, this month Steve explain how to improve your shots with dark frames.

Although in the excitement of the moment it is all too easy to forget about calibratin­g your images, the rewards of carrying out this task far outweigh the extra time required to do so. Dark frames play an important part in the production of quality deep-sky images, removing unwanted noise artefacts.

As your camera’s sensor warms up during the long exposures required for deep-sky imaging, the temperatur­e increase is misinterpr­eted as light, producing thermal noise that is overlaid on your image data. Longer exposures generate greater levels of thermal noise, especially with DSLR cameras as these don’t have the benefit of a Peltier cooling system to keep them at a temperatur­e many degrees below ambient.

Thermal noise has two different forms: an overall mush of noise and the more obvious ‘hot pixels’ that show as bright dots of light. Dark frames – that is, frames taken with the same settings as your main image frames but with the lens cap on – can help you to deal with this. It is important that dark frames should match the parameters used for capturing your deep-sky images with regard to exposure length, ISO number (where appropriat­e) and temperatur­e. This ensures that the noise profile of the two image types can cancel one another out during the calibratio­n process, thus removing the thermal noise to a large extent.

Matching parameters

The exposure length and ISO are easy to replicate, but temperatur­e is harder to match with a DSLR camera than with an astronomic­al CCD that has Peltier cooling. With a DSLR camera you should capture your dark frames in similar ambient conditions to your image frames, ideally during the same imaging session.

If your CCD has set-point cooling you can use what are known as ‘library darks’. These are a set of dark frames taken at some previous time that can be re-used again and again, although you should refresh them every six months or so to compensate for ageing in the sensor. You should store a range of dark frames taken at different exposure lengths to ensure an accurate match to subsequent image frames.

You should aim to capture 16-30 dark frames for conversion into a single master frame to average out the noise artefacts and increase the signal to noise ratio. This ensures that the dark frame doesn’t add any unwanted noise of its own to your images.

You download your dark frames from a camera in exactly the same way as your image frames so, in addition to holding a facsimile of the thermal noise profile of your sensor, dark frames also hold the bias data for your sensor. As both bias frames and dark frames need to be subtracted from your images during calibratio­n, you can also use your dark frames to bias correct your images. However, if you are calibratin­g with flat frames, as we discussed last month, a set of bias frames will still be required to calibrate the flats.

Although there are numerous programs that can be used to apply dark frames, here we’re going to concentrat­e on two popular packages – DeepSkySta­cker (free) and MaxIm DL (commercial).

In DeepSkySta­cker, select the calibratio­n files along with the image data files by clicking, in turn, Open Picture Files > Dark Files; Flat Files; Dark Flat Files; and finally Offset/Bias Files. Of course, if you are only applying dark frames, you can ignore the other

 ??  ??
 ??  ?? A single dark frame (left) displays much more random noise than a stacked master dark frame (right) – as is clear to see in the blown up areas
A single dark frame (left) displays much more random noise than a stacked master dark frame (right) – as is clear to see in the blown up areas
 ??  ??
 ??  ??

Newspapers in English

Newspapers from United Kingdom