- By Tim Carter Tribune Content Agency

Q: I’ve built a free-standing treehouse for my 9-year-old son, but I’m a novice in carpentry. I recorded a video showing my nearly finished project. I’d like you to watch. I’m wondering if using 3⁄8-inch galvanized bolts in 4x4 posts was sufficient. I had a profession­al carpenter visit yesterday, and he said he would not worry about it, that the structure should last 20 years. But my son means the world to me, and I just want to be sure that I haven’t created a death trap. Thanks for your help.

A: The instant I read the reader’s overnight email, I watched his video. I’ve got it archived on my AsktheBuil­der.com website. You should watch it too because it’s filled with love and concern. But it’s also filled with serious building errors. I don’t want you to make the same mistakes when you build something for your child or grandchild. Just type “free standing treehouse” into the search engine at my site to get to the video.

Seconds after watching the video, I emailed the reader back. It was so important, I would have dialed him up if he had included his phone number. I told them to STOP WORKING on the treehouse and wait for a recording I would make to help him fix the errors. I also told the reader I would draw up a few simple sketches illustrati­ng what he needed to do. I used to draw these years ago sitting at a dining room or kitchen table for customers as I explained how I was going to build something for them.

Let’s run down the list of errors made in the constructi­on of the treehouse. The first one, in my opinion, was a lack of research before he got out his tools. I say this not knowing exactly what the reader did, but if he did do any, he either got very bad advice or, if he found great advice, he failed to follow it. The internet is overflowin­g with conflictin­g building advice, and if you don’t know what’s right and what’s wrong, it’s easy for you to go down the wrong path.

Allow me to describe what was built. For simplicity, the reader built a 12 foot by 12 foot deck in the air. The top of the platform is about 6 feet in the air and the entire structure is supported by eight 4x4 posts.

This is where all the problems started. I also frequently see profession­al carpenters make this mistake. The reader bolted the outer 2x6s to the 4x4 posts. He had two 3/8-inch diameter bolts at each post. Can you imagine how much weight is bearing on these bolts? The entire surface area of the top half of the two bolts at each post only adds up to 1.17 inches times the thickness of the 2x6. Realize the actual point loading is much more severe because the surface area of bolt contact through the 2x6 is a halfcircle, not a flat spot like you might find on top of a post or column.

They should have used a notched 6x6 post so the outer 2x6 beam rests on solid wood. The weight would be directly transferre­d to the buried concrete piers in the ground. I suggested he fix this error by attaching a treated 2x4 to each 4x4 post. This new piece of lumber would extend from under the 2x6 down to the top of the concrete pier in the soil.

As I watched more of the video, I saw they had used what appeared to be galvanized drywall screws to attach the joist hangers to the outer beams. Drywall screws are not structural screws. You can buy special structural bolts made to fasten joist hangers to beams.

Later in the video, they brought up how when you stand up on the deck it sways back and forth. No doubt it would! With very little effort a group of boys celebratin­g a victory in a mud ball war with friends on the ground could get the entire structure to collapse, as the legs would fold under with very little effort.

This defect can be solved with ease by installing full-length diagonal bracing on both sides of two opposing corners of the structure. A treated 2x6 could be fastened to the top of each corner 4x4 and angle down to the bottom of the center 4x4. This is how builders of structural steel buildings prevent racking. They’ll use solid steel or tensioned steel cables for the diagonal brace.

Another serious defect was the railing at the top of the deck. The reader took 4x4 posts, notched them, and just bolted these to the sides of the 2x6 outer beam. When you notch a piece of wood, it’s only as strong as the remaining piece of wood. In his case, he no longer had 4x4s, but a 2x4 railing. This is completely unacceptab­le. There are special metal connectors that are made that will exceed the minimum code requiremen­ts for deck railing safety. I showed these to the reader, and you can see a video about these on the same page where I have the treehouse video.

 ?? TIM CARTER ?? In this screen grab of a video the reader sent, you can see the treehouse they built for their son that includes several critical errors.
TIM CARTER In this screen grab of a video the reader sent, you can see the treehouse they built for their son that includes several critical errors.