For the control settings used here go to soundandvi­sion. com. The measuremen­ts were made using CALMAN measuremen­t software from Portrait Displays, together with X-rite i1pro3 Plus and Klein’s K-10A color meters and a Fresco 6G pattern generator from Murideo.

HD/SDR

FULL- ON/FULL- OFF CONTRAST RATIO: Unmeasurab­le

In the Filmmaker Picture Mode and its out-of-the-box picture settings, the peak white level was 70 foot-lamberts (240 nits) and the black level 0.000 foot-lamberts, rendering the full-on/full-off contrast ratio unmeasurab­le. The grayscale Delta E values ranged from a low of 1.49 at 30% to a high of 2.24 at 90%. The pre-calibratio­n color Delta E values ranged from a low of 0.76 in blue to a high of 1.91 in red. The gamma was a tight match to BT.1886 (the standard for non-high dynamic range sources).

While these results were excellent, I found 70 ft-l to be a bit too bright for comfortabl­e viewing of standard dynamic range sources. I reduced the output to just under 54 foot-lamberts (185 nits). and adjusted the settings for the best-calibrated results.

The grayscale Delta Es then ranged from a low of 0.09 at 100% to a high of 1.3 at 50%. The calibrated color Delta Es measured a low of 0.86 in blue and a high of 2.18 in red.

A Rec.709 Saturation Sweep, analyzing all primary and secondary colors at saturation levels from 20% to 100%, produced a consistent­ly good result with all Delta E values below 4.0 (the latter for cyan at 20%). On a color checker test, which samples dozens of real-world colors for accuracy, the maximum Delta E was 3.7 and the average 2.0. The S95B had excellent uniformity on a full field white pattern, with no sign of the “dirty screen effect.”

(Delta E is a figure of merit that indicates how closely a display adheres to the color standard. Experts generally agree that at levels below 3.0-4.0—most argue for 3.0—the result is visibly indistingu­ishable from perfect tracking. Delta E values may be used to characteri­ze the accuracy of both white balance [grayscale] and color.)

The S95B passed all of our standard 1080p video tests for glitch-free upconversi­on, luma, and chroma resolution, and above and below black and above white levels. The input lag in Filmmaker mode measured 70ms. Our 1080p Bodnar measuremen­t device would not lock on with Game Mode active, so I was unable to measure game mode lag.

HD/ HDR

FULL- ON/FULL- OFF CONTRAST RATIO: Unmeasurab­le

In the HDR10 Filmmaker Picture Mode’s default settings, the peak brightness was 1004 nits (293 ft-l, the brightest OLED we’ve yet measured) and the black level 0.000 nits, for an unmeasurab­le full-on/ full-off contrast ratio. The HDR EOTF (Electro-optical Transfer Function—roughly the gamma for HDR) was a nearly perfect match to the EOTF standard.

Before calibratio­n, the grayscale Delta E’s ranged from a low of 0.4 at 20% to a high of 3.9 at 100% (the maximum was 2.4 at or below 70%, the approximat­e knee of the EOTF curve). The minimum Color Delta E (at 50% stimulatio­n) was 0.5 in blue and the maximum 2.4 in cyan.

After calibratio­n, the minimum grayscale Delta E was 0.29 at 20% and the maximum 3.7 at 70% (no other level was above 2.5). The post-calibratio­n color Delta Es were a minimum of 0.6 in green and a maximum of 2.2 in cyan.

The HDR 100% peak white levels, with luminance windows of varying sizes, measured 1000 nits from windows of 1% to 10%, 600 nits at 25%, 300 nits at 50%, and 200 nits at 100%. On an HDR Color Checker test (sampling a wide range of realworld colors and not just the primaries and secondarie­s), the S95B averaged a Delta E of 1.28 (2.79 maximum) with luminance included and 1.09 (2.79 max) without luminance. P3 and BT.709 saturation sweeps inside BT.2020 were both very good. The S95B

 ?? ?? Fig.2 Calibratio­n yields even higher accuracy, but the difference versus uncalibrat­ed and calibrated is not all that large.
Fig.2 Calibratio­n yields even higher accuracy, but the difference versus uncalibrat­ed and calibrated is not all that large.
 ?? ?? Fig.1 Even without calibratio­n the S95B QD-OLED'S picture exhibits commendabl­e accuracy,
Fig.1 Even without calibratio­n the S95B QD-OLED'S picture exhibits commendabl­e accuracy,

Newspapers in English