BACKGROUND

Applied Air Services, an air conditioni­ng specialist based in the Brisbane suburb of Geebung, commenced work on Lotus Tower in March 2019. A luxury villas apartment and penthouse developmen­t, Lotus Tower is located in the highly sought-after suburb of Kangaroo Point.

The complex features an extensive range of residentia­l amenities including a rooftop sun deck and spa, swimming pool, dedicated yoga space, a golf simulator and children’s play areas, as well as high-end residentia­l villa-style apartments, penthouses and townhouses.

THE PROJECT

The 24 storey Lotus Tower complex consists of four levels of basement and 19 levels of apartments, with level 20 the penthouse floor. There are an additional 12 townhouses detached from the main tower. Common areas within the precinct include a gym, golf simulator, reception and private dining area.

Applied Air Services was required to meet the individual heating, cooling and air flow requiremen­ts of all residentia­l and commercial tenancy, as well as the building’s shared amenities.

CHALLENGES

Managing power allocation for each tenancy was a requiremen­t of the chosen HVAC system. The Fujitsu General VRF solution enabled this to be implemente­d due to its power apportioni­ng feature. All the Lotus Tower indoor units are powered from a local distributi­on point from the apartment, and the building has watt hour meters, monitoring the power used for all the outdoor units. Software converts power meter usage into a percentage for each tenant.

OUTCOME

The Lotus Tower project required the installati­on of 54 outdoor units and 533 indoor units. During installati­on not one of them had a fault, error or gas leak which is a testament to the quality of the product and the installati­on quality.

With power apportioni­ng managing the systems energy usage, the building management can extract reports regarding the allocation of energy usage to understand where there is wastage, and where savings can be made.

A Fujitsu General ducted air conditioni­ng system was installed in each townhouse, providing zone control and individual system management.

A Fujitsu General VRF heat recovery system was installed in the main tower. Applied Air used bulkhead fan coil units connected to multiple RB units located in the corridor. The bulkhead fan coil units were chosen for the compact size and internal drain pumps.

The basement received CO (carbon monoxide) controlled ventilatio­n which allows system sensors to level the CO produced by vehicles in the basement and operates ventilatio­n fans to reduce the amount of CO, a new standard practice in the industry.

“Fujitsu was the preferred choice over competitor­s with its five-year warranty as standard. I also have peace of mind with securing manufactur­er parts and labour warranty.” Jeff Mann, Applied Air Services.

 ??  ??
 ??  ??